Five things worth checking before you ring us
Something is not cooling. What can I check myself in two minutes before I pay for a call out?
Published 13/11/2026. Written by the Pristine Cooling team, Kalgoorlie.
Five things, two minutes, no tools. Check the power, check the door, check whether the controller is mid defrost, check the condenser can breathe, then ask what changed today. About one in five call outs turns out to be something like this. We would genuinely rather you found it yourself than paid for a call out so we could walk in and flick a switch.
None of this involves opening anything or touching anything electrical. If a check points at a real fault, that is the moment to stop looking and ring.
1. Is it actually getting power
Start here, because it is the one that gets missed.
Look at the isolator switch near the unit. Look at the breaker in the board. On a commercial site the most common reason either is off is that somebody turned it off on purpose, for a clean or a repair or a delivery, then went home.
One important difference. A switch somebody flicked is a switch. A breaker that has tripped is a fault telling you something. If you reset it once and it holds, fine, note that it happened. If it trips again, leave it off and ring us. A breaker that keeps tripping is protecting you from something. Resetting it over and over until it stays in is how a small electrical fault becomes a fire.
2. Is the door actually shut
Obvious, which is exactly why nobody looks.
Walk up to it and put your hand on it. Is it pulled up tight? Is something stacked against it stopping it closing the last inch? Have the strip curtains been tied back because they were annoying during a stocktake? Is there a pallet under the bottom edge?
A cool room with a door that is not quite closed will run all day without ever getting there. It looks exactly like broken gear.
3. Is the controller mid defrost
This is the one that saves the most unnecessary call outs.
Every refrigeration system melts the ice off its coil on a schedule. While that is happening the room reads warmer than its setpoint, because it is meant to. Depending on the system a defrost runs for something like twenty minutes, then the room pulls back down.
So a controller showing a temperature above setpoint is not automatically a fault. If the display says defrost or a defrost light is on, note the time and come back in half an hour. If it has pulled back down, nothing was ever wrong. If it is still climbing an hour later, now you know something.
Have a look for a fault code on the display too. Write down exactly what it says, including the numbers. That code is often the single most useful thing you can tell the technician on the phone.
4. Can the condenser breathe
The condenser is the part that throws the heat away, usually outside or on the roof. It needs clear air across it.
Go and look at it. Has a delivery been stacked in front of it? A bin moved? Has somebody put up shade cloth over it, meaning well? Is the coil itself packed with red dust to the point where you cannot see light through the fins?
Out here that last one is the most common cause of a room that will not hold. We wrote about why in your cool room is not holding temperature.
5. What is different today
The most useful question on the list, because refrigeration rarely changes its mind for no reason.
Was there a power outage overnight? Some equipment does not restart itself after one. Has a new oven, dishwasher or hot water unit been installed near the plant? Did a delivery double the amount of warm product put in at once? Did the cleaners come through? Has anybody been on the roof?
A system that worked on Tuesday is usually responding to something that happened on Wednesday. Finding that thing is half the diagnosis.
Any one of those five can look exactly like a system that has died, which is why they are worth two minutes before the phone comes out.
The one thing not to do
Do not sit there resetting it.
Switching a refrigeration system off and straight back on repeatedly does real damage. A compressor that restarts against pressure, over and over, is being worked far harder than it was built for. People do it because it sometimes seems to help for ten minutes.
You also lose the evidence. Most controllers hold a fault log, alarm history and the temperature the room actually reached. Cycling the power can clear all of it, which means the technician who arrives is now diagnosing from scratch instead of reading what happened.
Leave it running. Leave the door shut. Ring us.
If it is none of the five
Then it is a real fault, which is what we are for.
Our after hours line is for commercial sites. You do not need an account with us to ring it. The after hours call out is a flat fee with the first four hours of same day labour inside it. Parts get quoted before anything is fitted. Travel beyond 20km from our Boulder Road workshop is quoted before we book it. All of it is set out on the 24/7 Breakdown and Repairs page.
When you ring, have the temperature and the time you read it, the fault code if there is one, whether the fans are still running, what the coil looks like and what is in the room. That last one sets the order of the day more than anything else.
If you would rather not have this conversation at 11pm at all, that is what preventative maintenance is for. Most of what fails gets caught on a scheduled visit months before it becomes a night call. See what we look after on the commercial refrigeration page.
Ring us and we'll tell you when we can be there
Same number either way. Ring it if something is down right now or if you want a quote, a service or a maintenance contract set up.